Signal Tracing
The signals shown on the target PC stop updating while the target
application continues running, and the target PC displays the following
message:
Scope: 1, set to state 'interrupt ed'
2 Stop the target application. For example, to stop the target application
xpcosc, right-click xpcosc and select Stop.
The target application on the target PC stops running, and the target PC
displays the following messages:
minimal TET: 0.0000006 at time 0.001250
maximal TET: 0.0000013 at time 75.405500
Note that if you stop the ta rget application before stopping the scope, the
scope stops, too.
Ifyouhavefilescopes,youcancopythefilethatcontainsthesignaldatafrom
the target PC to the host PC. See “Copying Files to the Host PC” on page 3-35.
Software Triggering Scopes
You can set up a scope such that only a user can trigger the scope. This
section assumes that you have added a scope to your targe t application (see
“Creating Scopes” on page 3-17) and that you have added signals to that scope
(see “Adding Signals to Scopes” on page 3-24).
1 In the xPC Target Explorer w indow , select the scope that you want to
trigger by software. For example, select
Scope 1.
The properties pane for that scope is d isplayed.
3-29