MATLAB CONTROL SYSTEM TOOLBOX 9 Guía de usuario Pagina 440

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 649
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 439
d2c
11-50
Convert Hc back to discrete time by typing
c2d(Hc,Ts)
yielding
Zero/pole/gain:
(z+0.5) (z+0.2)
-------------------------
(z+0.5)^2 (z^2 + z + 0.4)
Sampling time: 0.1
This discrete model coincides with after canceling the pole/zero pair at
.
See Also c2d Continuous- to discrete-time conversion
d2d Resampling of discrete models
logm Matrix logarithm
References [1] Franklin,G.F., J.D. Powell, andM.L . Wo rkman,DigitalControlofDynamic
Systems, Second Edition, Addison-Wesley, 1990.
[2] Kollár, I., G.F. Franklin, and R. Pintelon, “On the Equivalence of z -domain
and s-domain Models in System Identification,” Proceedings of the IEEE
Instrumentation and Measurement Technology Conference,Brussels, Belgium,
June, 1996, Vol. 1, pp. 14-19.
Hz
()
z 0.5
=
Vista de pagina 439
1 2 ... 435 436 437 438 439 440 441 442 443 444 445 ... 648 649

Comentarios a estos manuales

Sin comentarios