MATLAB EMBEDDED IDE LINK 4 - FOR USE WITH TEXAS INSTRUMENTS CODE COMPOSER STUDIO Guía de usuario Pagina 482

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 575
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 481
Tar get Preferences
SYSCLKOUT
escaler2*Pr
with the exception of zero. When Qualication sampling
period prescaler
=0, a sample is taken every SYSCLKOUT
clock tick. For example, a prescale setting of
0 means that a
sampleistakenoneachSYSCLKOUTtick.
The following gure shows the SYSCLKOUT ticks, a sample
taken every clock tick, and the Qualication type set
to
Qualification using 3 samples.Inthiscase,the
Qualication sampling period prescaler
=0:
In the next gure Qualication sam pling period
prescaler
=1. A sample is taken every two clock ticks, and
the Qualication type is set to
Qualification using 3
samples
. The output signal changes much later than if
Qualication sampling period prescaler
=0.
In the following gure, Qualication sam pling period
prescaler
=2. Thus , a sample is taken every four clock
ticks, and the Qualication type is set to
Qualification
using 3 samples
.
9-90
Vista de pagina 481
1 2 ... 477 478 479 480 481 482 483 484 485 486 487 ... 574 575

Comentarios a estos manuales

Sin comentarios